Maximum Measurement Error: Accuracy ≤±1.5% FS (typical), ≤±1.0% FS (maximum)Measurement Range: Liquid: 2.5 ~ 1,000,000 L/h; Gas: 0.07 ~ 3,000 m³/h;Range ratio: 10:1, 20:1
-
● Clamp-on design requiring no piping modifications. ● Reliable measurement even for small 1/4 tubing and ultra-low flow rates down to 0.01 ml/min. ● Compatible with a wide range
-
Maximum Measurement Error: Mono ±1%, stereo ±0.5%, quadraphonic ±0.5%Measurement Range: 0.0254-14130 m³/hMedium temperature range: -30~160°CMaximum process pressure: Wetted Parts
-
Maximum Measurement Error: ≤±1.0% of rangeMeasurement Range: 0.1-1800 m³/hMedium temperature range: -30...100°C/150°C/180°CMaximum process pressure: 1.6-40MPaWetted Parts
-
Maximum Measurement Error: Volumetric flow rate (standard operating conditions): ±0.5% reading ± 1 mm/s (0.04 in/s)Measurement Range: 0.04 m³/h to 1000 m³/h, 1:10/20Medium
-
Maximum Measurement Error: ≤±1.5% FS (maximum)Measurement Range: 3.0m³/h to 6000m³/hMedium temperature range: -20 ~ +70 °CMaximum process pressure: 4.0 MPa (DN25-DN50)Wetted Parts
-
Maximum Measurement Error: ±0.5% of reading (within 1:20 range ratio), ±1% of reading (full range).Measurement Range: 0.6 ~ 20000 L/h (corresponding to models HNF30-02 ~
-
Maximum Measurement Error: ±2%Measurement Range: 1~120L/minMedium temperature range: 0-100℃,-10-90℃,customizableMaximum process pressure: Wetted Parts Material: Stainless Steel 304
-
Maximum Measurement Error: Measurement Range: 0.5-400 L/minMedium temperature range: -20~100°CMaximum process pressure: 10bar (Maximum pressure resistance 16bar)Wetted Parts
-
Maximum Measurement Error: Display accuracy: ±3% F.S.; Analog output accuracy: ±3% F.S.; Repeatability: ±1% F.S.Measurement Range: Model HNF80-A-501: 5-500 L/min; HNF80-A-102:
-
Maximum Measurement Error: Measurement Range: 1...150 cm/s (water), 3...300 cm/s (oil), 20...2000 cm/s (air)Medium temperature range: -20~90℃Maximum process pressure: Wetted Parts
-
Maximum Measurement Error: ±2.5% of Full ScaleMeasurement Range: 20-1800 L/minMedium temperature range: Maximum 90 ℃Maximum process pressure: 16 barWetted Parts
Our range consists of Digital Metal Tube Rotameter (variable area flow meter), Digital Gas Flow Meter, Digital Steam Jacket Flow Meter, Metal Tube Rotameter. Glass Tube Rotameter,...
Origin of Metal Tube Rotameter. It works on the law of variable area – the fluid in metal tube upraised a float in taper tube, which increases the area of fluid passage. The float moves up...
Aug 08, 2021 · Digital Metal Tube Rotameter | Manufacturer-Best price. The Metal Tube Rotameter uses the variable area measurement principle. The intelligent metal tube float...
The Digital Metal Tube Rotameter is used for flow measurement where current output with totaliser is required. Metal Tube Rotameters are rugged, versatile and accurate variable area (VA) flow meter...
Metal tube variable area flow meter has the merit of little volume, broad measuring range and convenience for use. Rotameter variable area flow meter can be used to measure liquid, gas and vapor flow...
DIGITAL METAL TUBE ROTAMETER V-TECH” make Digital Metal Tube Rotameter is used for ow measurement where current output with total is required. WORKING PRINCIPLE It...