Products
Metal Tube Flow Meter
video
Metal Tube Flow Meter

Metal Tube Flow Meter

The HNF50 Metal Float Flow Meter is designed for reliable flow measurement of liquids and gases in demanding industrial environments.
Based on the variable area principle, it combines a rugged all-metal construction with stable magnetic coupling transmission, making it suitable for high temperature, high pressure, corrosive, and hazardous process conditions.
Available with local indication, 4-20mA output, HART, pulse, and RS485 communication, the HNF50 is widely used in water treatment, chemical processing, utilities, and industrial manufacturing systems.

Hongnuo (shenyang) General Machinery Co., Ltd. is one of the most reliable manufacturers and suppliers of metal tube flow meter in China. Welcome to buy high quality metal tube flow meter at competitive price from our factory. We also accept customized orders.

 

 

Key Specifications

 

 

Parameter Specification
Measurement Range

Liquid: 1–150,000 L/h

Gas: 0.05–3,000 m³/h

Accuracy

±1.5% FS (Standard)

±1.0% FS (Optional)

Process Temperature

-30°C to 120°C Standard

Up to 350°C High-Temperature Version

Process Pressure Up to 4.0 MPa
Output Signals 4-20mA, HART, Pulse, RS485 Modbus

 

Please see the Specifications for more details. 

>View all specifications

 

 

Product Features

 

Built for Demanding Process Environments

The HNF50 metal float flow meter combines a robust all-metal measuring system with a proven variable area design. It is suitable for liquid and gas flow measurement in applications involving high temperature, elevated pressure, or corrosive media.

 

Key Benefits

All-metal construction for long service life

Available in 316L, PTFE-lined, titanium and Hastelloy materials

Low pressure loss across the measuring range

Local indication with optional remote signal output

Suitable for both liquid and gas measurement

Multiple communication options including 4-20mA, HART and RS485

 

HNF50 2

Designed for reliable performance in chemical processing, water treatment, utility systems and industrial manufacturing.

 

.

 

 

 

 

How Variable Area Measurement Works

 

 

Simple Principle. Reliable Measurement.

The HNF50 operates using the variable area measurement principle. As the process fluid flows upward through the tapered measuring tube, the float rises until the upward flow force balances its weight.

The float position changes proportionally with flow rate, providing a direct indication of the measured flow. Through a magnetic coupling mechanism, the movement is transmitted to the indicator and output module without direct mechanical contact.

HNF50 1


 

A proven measuring method widely used for continuous monitoring of liquid and gas flow in industrial processes.

 

 

Typical Applications

 

 

Reliable Flow Monitoring Across Industries

The HNF50 is designed for applications where stable flow measurement is required under varying process conditions.

 


 

Chemical Processing

Monitoring acids, alkalis and process chemicals with corrosion-resistant material options.

 


 

Water Treatment

Flow measurement in filtration systems, dosing units and distribution pipelines.

 


 

Utilities & Energy

Suitable for cooling water, compressed air and thermal process applications.

 


 

Pharmaceutical Manufacturing

Reliable monitoring in utility systems and controlled production environments.

 

 

HNF50 3

Available in standard, corrosion-resistant, sanitary and high-temperature configurations to meet different process requirements.

 

 

 

 

HNF50 Metal Float Flow Meter

Specific Parameters

Value / Description

Measurement Principle

Adopting the variable area measurement principle, it is suitable for flow measurement of liquids and gases. All metal structures, including pointer type, electric remote transmission type, corrosion-resistant type, high-pressure type, jacket type, and explosion-proof type. It is equipped with standard analog signal output and local indication.

Nominal Diameter Range

DN15 ~ DN150

Wetted Parts Material

The measuring tube and float materials are optional: 304 (0Cr18Ni9), 316 (0Cr18Ni12Mo2Ti), 316L (00Cr17Ni14Mo2), Hastelloy B/C, Titanium/Titanium Alloy, PTFE Lined. Hygienic surface roughness < 0.8Ra

Connection Method

Standard type: Flange connection (standard GB/T9119-2000), flange clamp connection method can also be provided.

Maximum Measurement Error

Accuracy ≤±1.5% FS (typical), ≤±1.0% FS (maximum)

Measurement Range

Liquid: 2.5 ~ 1,000,000 L/h; Gas: 0.07 ~ 3,000 m³/h
Range ratio: 10:1, 20:1 (customizable)

Maximum Process Pressure

DN15, DN25, DN50: 4.0 MPa; DN80, DN100, DN150: 1.6 MPa

Medium Temperature Range

Standard type: -30℃ ~ +120℃; High temperature type: 120℃ ~ 350℃; PTFE lined: up to 80℃

Ambient Temperature Range

On-site type: -40℃ ~ 120℃; Remote type: -30℃ ~ 70℃

Transmitter Housing Material

Carbon steel or stainless steel (optional depending on the model)

Display/Operation

Provides 0-10mA and 4-20mA local indication, supports accumulation, digital communication, and field modification of measurement parameters

Inputs

Analog Input

Outputs

Two-wire: 4-20mA DC,
4-20mA+HART protocol;
Three-wire: MODBUS (RTU mode);
Accumulative pulse output (24V, 50% duty cycle);
Optional relay alarm

Power Supply

24VDC (12~36VDC); Lithium battery power supply; 220VAC

Certificate

CE Certification; Protection Level IP65; Explosion-proof type available (option)

Functional Safety

Ex ia IIC T1~T4 Ga

 

HNF50 177

HNF50 178

Send Inquiry