Maximum Measurement Error: ±0.5% of reading (within 1:20 range ratio), ±1% of reading (full range).Measurement Range: 0.6 ~ 20000 L/h (corresponding to models HNF30-02 ~
-
Maximum Measurement Error: Liquid: ±0.5% ±1.0% ±1.5%; Gas: ±0.5% ±1.0% ±1.5% ±2.5%Measurement Range: Liquid: 0.2-690000 m³/h; Gas: 3-3750000 m³/hMedium temperature range: Standard
-
Maximum Measurement Error: Low flow: ±10mL/min,High flow: ±2% RD;Measurement Range: 0-30000mL/min;Medium temperature range: 0℃ - 60℃;Maximum process pressure: 0.3MPa;Wetted Parts
-
Maximum Measurement Error: Flow ±1%, linearity ±0.5%; Heat ±2%; P3 accuracy calibrated to ±0.5% as per customer requirementsMeasurement Rate: 0~±10m/sMedium temperature
-
Maximum Measurement Error: Mono ±1%, stereo ±0.5%, quadraphonic ±0.5%Measurement Range: 0.0254-14130 m³/hMedium temperature range: -30~160°CMaximum process pressure: Wetted Parts
-
Maximum Measurement Error: ≤±1.5% FS (maximum)Measurement Range: 3.0m³/h to 6000m³/hMedium temperature range: -20 ~ +70 °CMaximum process pressure: 4.0 MPa (DN25-DN50)Wetted Parts
-
Maximum Measurement Error: Grade 0.5, Grade 1Measurement Range: 0.04-10 cubic meters per hourMedium temperature range: 0-100°C, CustomizedMaximum process pressure: Wetted Parts
-
Maximum Measurement Error: ±1.0%R (Typical), ±0.5%R (High Precision)Measurement Range: DN15: 1-10 m³/h to DN200: 240~3000 m³/hMedium temperature range: -20 °C ~ +120 °CMaximum
-
Maximum Measurement Error: Display accuracy: ±3% F.S.; Analog output accuracy: ±3% F.S.; Repeatability: ±1% F.S.Measurement Range: Model HNF80-A-501: 5-500 L/min; HNF80-A-102:
-
Maximum Measurement Error: Measurement Range: 1...150 cm/s (water), 3...300 cm/s (oil), 20...2000 cm/s (air)Medium temperature range: -20~85℃Maximum process
-
Maximum Measurement Error: ±5 Full ScaleMeasurement Range: 0.6-70L/minMedium temperature range: Maximum 90 ℃Maximum process pressure: 10bar (plastic), 50bar (aluminum profile),
-
Maximum Measurement Error: ±2.5% of Full ScaleMeasurement Range: 20-1800 L/minMedium temperature range: Maximum 90 ℃Maximum process pressure: 16 barWetted Parts
Rosemount™ 8800 Quad Vortex Flow Meter ADD TO WORKSPACE Compare Specifications Flow Meter Accuracy ± 0.70% of mass flow rate in water using 8800 MultiVariable (MTA/MCA option) ± 2% of mass flow in...
Vortex Steam Flow Meter COMATE VFM60MV multivariable vortex meter are designed to measure mass flow for saturated and superheated steam without the need for an external...
Rosemount™ 8800 Quad Vortex Flow Meter ADD TO WORKSPACE Compare Specifications Flow Meter Accuracy ± 0.70% of mass flow rate in water using 8800 MultiVariable (MTA/MCA...
The Rosemount™ 8800 MultiVariable Vortex Meter automatically adjusts for changes in density, making it easy to accurately measure mass and corrected volume in steam and liquid applications. With...
Prowirl 200 is the world’s first vortex meter with the option of monitoring the steam quality and immediately generating an alarm message in case of wet steam. Prowirl 200 can also be used for flow...
The multivariable vortex flow meter is ideal for high temperature, superheated, and saturated steam applications since it eliminates the need for separate components and associated...