Maximum Measurement Error: ≤±1.5% FS (maximum)Measurement Range: 3.0m³/h to 6000m³/hMedium temperature range: -20 ~ +70 °CMaximum process pressure: 4.0 MPa (DN25-DN50)Wetted Parts
-
Maximum Measurement Error: Liquid: ±0.5% ±1.0% ±1.5%; Gas: ±0.5% ±1.0% ±1.5% ±2.5%Measurement Range: Liquid: 0.2-690000 m³/h; Gas: 3-3750000 m³/hMedium temperature range: Standard
-
Maximum Measurement Error: Low flow: ±10mL/min,High flow: ±2% RD;Measurement Range: 0-30000mL/min;Medium temperature range: 0℃ - 60℃;Maximum process pressure: 0.3MPa;Wetted Parts
-
Maximum Measurement Error: Flow ±1%, linearity ±0.5%; Heat ±2%; P3 accuracy calibrated to ±0.5% as per customer requirementsMeasurement Rate: 0~±10m/sMedium temperature
-
Maximum Measurement Error: ≤±1.0% of rangeMeasurement Range: 0.1-1800 m³/hMedium temperature range: -30...100°C/150°C/180°CMaximum process pressure: 1.6-40MPaWetted Parts
-
Maximum Measurement Error: Volumetric flow rate (standard operating conditions): ±0.5% reading ± 1 mm/s (0.04 in/s)Measurement Range: 0.04 m³/h to 1000 m³/h, 1:10/20Medium
-
Maximum Measurement Error: Grade 0.5, Grade 1Measurement Range: 0.04-10 cubic meters per hourMedium temperature range: 0-100°C, CustomizedMaximum process pressure: Wetted Parts
-
Maximum Measurement Error: Measurement Range: 0.5-400 L/minMedium temperature range: -20~100°CMaximum process pressure: 10bar (Maximum pressure resistance 16bar)Wetted Parts
-
Maximum Measurement Error: ±1.0%R (Typical), ±0.5%R (High Precision)Measurement Range: DN15: 1-10 m³/h to DN200: 240~3000 m³/hMedium temperature range: -20 °C ~ +120 °CMaximum
-
Maximum Measurement Error: Display accuracy: ±3% F.S.; Analog output accuracy: ±3% F.S.; Repeatability: ±1% F.S.Measurement Range: Model HNF80-A-501: 5-500 L/min; HNF80-A-102:
-
Maximum Measurement Error: Liquid: ±0.1% ± (zero stability / actual flow) ×100%; Gas: ±0.25% ± (zero stability / actual flow) ×100% (accuracy classes available: 0.15, 0.2, 0.5,
-
Maximum Measurement Error: Measurement Range: 1...150 cm/s (water), 3...300 cm/s (oil), 20...2000 cm/s (air)Medium temperature range: -20~85℃Maximum process
Hoffer Flow Controls has been designing and manufacturing quality turbine flowmeters and related process instrumentation for more than fifty years. Our initial experience was in the field of Sanitary...
Sanitary Turbine Flow Meter Features and Advantages: Accurate Measurement, Cost-effective and Minimal Maintenance Required; Excellent Repeatability 0.05%~0.2%;The repeatability of...
Sanitary Turbine Flow Meter is mainly used for volumetric total flow and flow rate measurement, and the working principle is relatively simple. It is used worldwide as a reliable, cost-effective...
Sanitary Flow Meters. Industrial Tri-Clamp; 3A-Sanitary High Accuracy. 1" 6.7-67 GPM; 1-1/2" 17.7-177 GPM; 2" 33-330 GPM; Positive Displacement Meter. Lube-Meter Aluminum FNPT; Oval...
Jan 23, 2021 · Edit Model Options. Accuracy Value ±0.5% of reading or better. Maximum Ambient Temperature 232°C (450°F) Output Signal 10 mV rms or greater into a 10 kkΩ load at minimum...
Sanitary flow meters and flow switches for efficient process control in many applications in the food industry, dairies, breweries, and beverage plants Call Us: 800-833-0081 Login...