Hongnuo (shenyang) General Machinery Co., Ltd. is one of the most reliable manufacturers and suppliers of magnetic float type level switch in China. Welcome to buy high quality magnetic float type level switch at competitive price from our factory. We also accept customized orders.
Specs at a glance
| Parameter | Value |
|---|---|
| Level output | Reed switch (NO/NC selectable) – single or dual point |
| Temperature output | PT100 / K-type thermocouple / Temperature switch (NO/NC) |
| Level switch points | 1 or 2 (customer specified) |
| Max pressure | 20bar (brass) / 60bar (stainless) |
| Max temperature | 105°C |
| Material (housing) | Brass or SUS304 stainless steel |
Single level switch vs Level + Temperature
| Feature | HNL10-A (Level only) | HNL10-B (Level + Temperature) |
|---|---|---|
| Function | Level switch only | Level switch + Temperature sensor – two measurements in one unit |
| Tank openings needed | 1 | 1 (same as single level switch – saves space) |
| Level output | Reed switch (NO/NC) | Reed switch (NO/NC) – single or dual point |
| Temperature output | Not available | PT100 / K-type thermocouple / Temperature switch (NO/NC) |
| Max temperature | 80°C | 105°C |
| Max pressure | Standard | 20bar (brass) / 60bar (stainless) |
| Mounting | Thread (G1/2, R1/2) | Thread (G1) or Flange |
| Material options | 304 / 316 / PP / PVDF / PTFE | Brass or 304 stainless steel |
| Best for | Simple level control in standard tanks | Tanks where both level and temperature need monitoring |
Need level only? HNL10-A does the job.
Need level + temperature from one installation point? HNL10-B is the choice.
When will use it?
Hydrothermal tanks - Level control + temperature monitoring in one opening. Brass or stainless body for pressure up to 60bar.
Chemical reactors - Small batch reactors where both level and temperature must be controlled. PT100 output for precise temperature reading.
Oil tanks / hydraulic reservoirs - Level alarm + oil temperature monitoring. Temperature switch output triggers cooling fan or heater.
Boiler feed water tanks - Level control + feed water temperature monitoring. K-type thermocouple option for higher temperature range.
Heat transfer oil systems - Level + temperature in thermal oil tanks. Dual switch points available for high/low level alarm + temperature protection.

Installation
Material & Pressure
| Rule | Why |
|---|---|
| Brass = 20bar max | Standard industrial pressure |
| Stainless 304 = 60bar max | Higher pressure applications |
| Max media temp = 105°C | Do not exceed – sensor accuracy drifts above this |
| No plastic options on this model | Brass or stainless only – HNL10-B is built for higher pressure/temperature |
|
HNL10-B Integrated Liquid Level and Temperature Switch Parameters |
|
|
Specific Parameters |
Value / Description |
|
Measurement Principle |
The HNL10-B is an integrated level/temperature switch with multiple standard control lever lengths, suitable for use in small oil and water tanks to detect liquid level and temperature. |
|
Product Type |
Level switch |
|
Float Type |
NBR float (for oil) |
|
Measurement Range |
0-1000mm, Customization |
|
Measurement Accuracy |
±5mm, Customization |
|
Outputs |
PNP,NPN |
|
Power Supply |
24VDC |
|
Operating Temperature |
-20-80℃ |
|
Material |
Brass,304 Stainless steel |
|
Process Connection |
Threaded, Flange |
|
Electrical Connection |
Hessmann, M12 Connector |
|
Protection Level |
IP65 |
|
Certificate |
CE certified |