Products
Radar Tank Level Sensor
video
Radar Tank Level Sensor

Radar Tank Level Sensor

HNL110-A Radar Level Gauge
Non-contact level measurement for liquids, slurries, and solids. 26GHz or 80GHz electromagnetic pulse. Unaffected by dust, steam, foam, or temperature changes.
Accuracy: ±3mm. Range: up to 70m.
Pressure: up to 200bar. Temperature: up to 250°C.
4-20mA with HART. Exd IICT5. For silos, tanks, reactors — where other sensors fail.

Hongnuo (shenyang) General Machinery Co., Ltd. is one of the most reliable manufacturers and suppliers of radar tank level sensor in China. Welcome to buy high quality radar tank level sensor at competitive price from our factory. We also accept customized orders.

 

 

How it works

 

 

HNL110-A

 

Antenna emits microwave pulse. Pulse reflects off the media surface. Electronics measure the time-of-flight - calculates distance to the media. Unaffected by dust, steam, foam, or temperature. No calibration needed.

 

 

 

Parameter overview

 

 

Parameter Value
Measuring range Up to 70m
Accuracy ±3mm
Repeatability ±3mm
Resolution 0.03% FS (max 1mm)
Response time <1s (0-60s adjustable)
Frequency 26GHz or 80GHz (selectable)
Output 4-20mA with HART

 

>View all specifications

 

 

 

 

Radar vs Ultrasonic – which one do you need?

 

 

Feature Ultrasonic (HNL100-A) Radar (HNL110-A)
Measurement principle Sound wave (mechanical wave) - requires air to transmit Electromagnetic wave (microwave) - no medium needed
Performance in dust Poor - dust attenuates the signal Excellent - penetrates dust
Performance in steam / mist Poor - steam scatters the signal Excellent - unaffected
Performance in foam Poor - foam absorbs the signal Excellent - penetrates foam
Effect of temperature Affected - speed of sound changes with temperature Not affected - speed of light is constant
Accuracy ±0.3% F.S. (varies with range) ±3mm (fixed - independent of range)
Measuring range Up to 40m Up to 70m
Pressure rating Normal pressure Up to 200bar
Temperature range Normal Up to 250°C
Blind zone Larger (0.4-2m) Smaller
Frequency 20–350KHz 26GHz or 80GHz
Price Cost-effective Higher performance - higher value
Best for Clean liquids, water treatment, simple tanks Silos, reactors, harsh conditions, high temp/pressure

 

Quick selection guide:

Clean liquid, ambient conditions, budget-sensitive? → Ultrasonic is a good fit.
Dust. Steam. Foam. High temperature. High pressure. Need reliable measurement in harsh conditions? → Radar is the right choice.

 

What our customers say:

"Switched from ultrasonic to radar on our cement silos. Ultrasonic gave unstable readings when the silo was being filled (dust). Radar works consistently - no dropouts."

 

What makes this different

 

 

 
 
product key technologies
HNL110-A 1

80GHz high-frequency radar - extremely small beam angle, concentrated energy

80GHz option provides a more focused beam. Less interference from tank walls, pipes, or internal obstructions. More reliable measurement in tight installations.

 

Unaffected by media characteristics

Dielectric constant. Density. Viscosity. Temperature. Pressure. None of these affect radar measurement. One sensor for almost any material - no calibration changes when media changes.

 

High temperature up to 250°C - high pressure up to 200bar

Standard model: -40°C ~ 85°C. Optional: up to 250°C. Pressure: up to 200bar. Use it in reactors, autoclaves, and high-temperature tanks where other sensors cannot go.

4-20mA with HART - and more

Standard 4-20mA with HART protocol. Connect to any DCS, PLC, or handheld communicator. Set up, configure, and troubleshoot from the control room

 

Exd IICT5 explosion-proof certified

For hazardous areas. Dust. Gas. Vapors. Install it where other sensors can't.

 

 Blowing horn antenna - keeps the antenna clean in dusty applications

Optional purged antenna prevents buildup on the horn. Cement. Fly ash. Powder. The antenna stays clean - readings stay accurate. No scheduled cleaning shutdowns.

HNL110-A - A

 

 

Where to use it

 

 

Cement & building materials Silo level measurement. Dust-filled environment. Ultrasonic fails - radar works. Blowing horn antenna keeps the lens clean.
Chemical / petrochemical Reactor and storage tank level. High temperature. High pressure. Corrosive media. PTFE-coated antenna for corrosion resistance.
Steel / metallurgy High-temperature applications. Parabolic antenna for extreme heat. Measures molten slag, hot materials.
Mining / mineral processing Ore silos, slurry tanks. Dust and particle interference. 80GHz narrow beam penetrates dust clouds.
Food & feed Silo level for flour, sugar, grains. PTFE coating for food contact. Exd option for flour dust hazardous area.

 

 

 
 

 

HNL110-A Radar Level Gauge - Reliable measurement where other sensors fail.

 

  • ±3mm accuracy | Up to 70m range
  • 26GHz or 80GHz | Up to 250°C | Up to 200bar
  • Unaffected by dust, steam, foam, or temperature
  • 4-20mA with HART | Exd IICT5
  • Standard horn / swept horn / high-temp parabolic antennas

 

 

Send us your tank/silo height, media type, temperature, pressure, and dust condition - we'll recommend the right antenna and configuration.

 

 

HNL110-A Radar Level Gauge Parameters

Specific Parameters

Value / Description

Measurement Principle

The HNL110-A radar level gauge antenna emits extremely narrow electromagnetic microwave pulses. These pulses propagate through the air at the speed of light. Upon encountering the surface of the measured medium, part of their energy is reflected back and received by the same antenna. The time interval between the transmitted and received pulses is proportional to the distance from the antenna to the surface of the measured medium.
Due to the extremely high propagation speed of electromagnetic waves, the time interval between the transmitted and received pulses is very small (on the order of nanoseconds) and difficult to determine precisely. The radar level gauge employs a special correlation demodulation technique to accurately identify the time interval between the transmitted and received pulses, thereby further calculating the distance from the antenna to the surface of the measured medium.

Product Types

Standard horn antenna, standard horn antenna with purge function, other antennas

Measuring Medium

Solid partices, slurry, water, oil media

Application Scenarios

Level, liquid level

Wetted Parts Material

304/316 stainless steel/PTFE coated (corrosion resistant)

Connection Method

Threaded connection
DN50-DN250 flange
DN50-DN250 universal joint flange
Customized

Electrical Connection

Terminal wiring

Measurement Range

0-1m,0-2m,0-3m,0-10m,0-15m,0-20m,
0-30m,0-40m,0-50m,0-60m,0-70m,
Customized

Withstand Pressure Reference

--40 bar (standard), -1-200 bar (optional)

Operating Temperature Range

-40-85℃ (standard), -40-150℃ (optional), -40-250℃ (optional)

Transmitter Housing Material

Aluminum

Outputs

4-20mA, 4-20mA with Hart

Power Supply

24VDC

Frequency

26GHZ,80GHZ

Protection Level

IP65 (standard), IP68 (optional)

Certificate

CE certified

Explosion-proof Selection

Non-explosion-proof type,Explosion-proof type

Dust Cover

Without dust cover,With dust cover

 

product-1600-2002

product-1600-2028

Send Inquiry