Products
Digital Dual Output Pressure Sensor
video
Digital Dual Output Pressure Sensor

Digital Dual Output Pressure Sensor

HNP20-C Digital Pressure Switch Equipped with imported pressure sensing core and digital signal processing circuit. The measuring range spans from 0.6 MPa up to 1000 MPa, with precision up to 0.25%FS. Two output configurations are available: dual-switch version with two independent relay outputs, or combined version featuring 4–20mA analog signal plus dual switch outputs. Users can freely configure trigger setpoints directly on site. Operating medium temperature ranges from -20 ℃ to 85 ℃, with 2 times overpressure resistance. Standard process connection is M20×1.5. Integrated local digital readout eliminates extra auxiliary tools for on-site parameter setup.

Hongnuo (shenyang) General Machinery Co., Ltd. is one of the most reliable manufacturers and suppliers of digital dual output pressure sensor in China. Welcome to buy high quality digital dual output pressure sensor at competitive price from our factory. We also accept customized orders.

 

 

Products Description

 

 

Parameter Specification
Product: Digital pressure sensor
Casing Material: 304 or 316 Stainless Steel
Wetted Material: 304, 316 or 316L Stainless Steel
Supply Voltage: Dual-point 15–36VDC; Single-point 19–36VDC
Pressure Connection: M20×1.5 external thread (standard); VCR and others optional

 

Please see the Specifications for more details. 

>View all specifications

 

 

 

Typical Applications

 

 

product-800-800

1. Hydraulic System Pressure Monitoring and Alarm

Hydraulic power stations, oil presses, injection molding machines, and other equipment require real-time display of system pressure and the ability to trigger alarms or shutdown protection when pressure is abnormal. The HNP20-C's dual-point output (two-way switching) allows direct setting of upper and lower limits; the switch activates when the pressure exceeds the limit, eliminating the need for external controllers and reducing system costs.


 

2. Pump and Valve Test Bench and Factory Testing

Pumps, valves, cylinders, and other hydraulic components undergo pressure resistance and leakage tests before leaving the factory. On-site operators must read and record pressure values ​​in real time. The digital display panel provides local readings, eliminating the need for external digital displays and reducing on-site instrument configuration and wiring workload.

 


 

3.High-Pressure Water Jet & Cleaning Equipment

This pressure switch supports measuring ranges up to 1000MPa, fully meeting pressure monitoring demands for ultra-high pressure water cutting and industrial cleaning machines. Built with an all-stainless steel body and optional VCR fittings, it delivers strong resistance against abrasion and corrosion caused by high-speed pressurized water media.

 

 

 

 

Why Choose Digital pressure sensor?

 

 

The HNP20-C features digital display and on/off control, directly replacing electric contact pressure gauges. The dual-point type provides two independent switching outputs, while the single-point type simultaneously outputs 4-20mA and two switching outputs. The setpoint is adjusted via panel buttons, requiring no external equipment. With no mechanical contacts, there are no vibration or oxidation issues, and the switch life is ≥100,000 cycles. The measuring range covers 0.6MPa to 1000MPa, accuracy can be selected according to requirements, multiple materials are available, and OEM and ODM are supported.

 

product-800-800

 


 

 

Key Advantages

 
  • High accuracy
  • Faster response
  • Stable performance
  • Small size
  • Easy to operate
  • Convenient and flexible installation

 

 

HNP20-C Electronic Pressure Sensor

Specific Parameters

Value / Description

Measurement Principle

Electronic pressure sensors are based on high-performance electronic components, using high-precision imported pressure sensitive components as the pressure measurement element. They adopt advanced digital circuits to convert the pressure signals sensed by the pressure sensitive components into current signals and switch signals. They have advantages such as high accuracy, fast response, stable performance, small size, easy operation, and convenient and flexible use and installation.

Casing Material

304 or 316 Stainless Steel

Wetted Material

304, 316 or 316L Stainless Steel

Supply Voltage

Dual-point type: 15~36VDC, single-point type: 19~36VDC

Pressure Connection

M20×1.5 external thread (standard configuration), VCR, etc.

Accuracy

1.0 level, 0.5 level, 0.25 level

Measurement Range

0~0.6MPa to 0~1000MPa

Input/Output Pressure Rating

2500VAC

Overpressure Limit

2 times full scale

Rated Current at Full Load

1ADC

Electrical Connection

M12 Connector

Media Temperature Range

-20~+85℃

Environmental Temperature Range

-20~+85℃

Signal Output

Dual Point Type: One set of normally open and normally closed switches each, when the pressure exceeds the upper limit, the switch state is converted; when the pressure falls below the lower limit, the switch state is restored. Single Point Type: One set of 4~20mA output and normally open and normally closed switches each, when the pressure exceeds the set value, the switch state is converted; when the pressure falls below the set value, the switch state is restored

Installation Method

Threaded Installation

Certification

CE, ISO9001, SIL

 

product-1600-938

product-1600-1700

Send Inquiry